Instruction sheet, Prs.4tec – Prescolite RDPSCFT User Manual
Page 2

www
.prescolite.com
• Prescolite
TollFree
Technical Support
1.888.PRS.4TEC
• Hours: 8am - 5pm ET
101 Corporate Drive • Spartanburg, SC 29303
With representatives offices in principal cities throughout North America.
Copyright 2005, 08/05 revision, All Rights Reserved - Printed in U.S.A.
Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143670100
Instruction
Sheet
5a. MAKE ELECTRICAL CONNECTIONS. CONNECT
GROUND WIRES TO GREEN GROUND LEADS.
CONNECT WHITE (COMMON) TO WHITE LEADS.
CONNECT POWER SUPPLY (LINE) TO BLACK
LEADS.
WARNING: DO NOT PINCH WIRES. CONSULT A
QUALIFIED ELECTRICIAN FOR ALL OTHER
OPTIONS THAT REQUIRE OTHER WIRING
CONFIGURATIONS.
5b. (DIMMING ONLY) CONNECT GRAY AND VIOLET
WIRES (SEE STEP #4b). DIMMING WIRE CONNEC-
TION MUST NOT BE MADE WITHIN BALLAST
HOUSING TO RETAIN CLASS 2 RATING FOR THE
DIMMING WIRES. MAKE THIS CONNECTION ONLY
AFTER PERFORMING STEP #4b.
IMPORTANT:
DIMMING FIXTURES: 0-10 VOLT CONTROL ONLY.
6. PUSH SLICES INTO THE BALLAST HOUSING.
7. FASTEN 2 HEX SCREWS (SUPPLIED) HALFWAY
INTO PENDANT BRACKET HOLES.
8. ASSURE THAT RETAINER RING IS PUSHED DOWN
OVER BALL HALVES AND SNAPPED INTO COVER
PLATE (PENDANT).
12. INSTALL THE DESIRED REFLECTOR AFTER ALL
CEILING INSTALLATION AND FINISHING WORK IS
COMPLETE.
*SEE INSTRUCTION SHEET 1077-**** FOR DPR8 &
DPR10 SERIES REFLECTORS.
*SEE INSTRUCTION SHEET 1079-**** FOR DPRL &
DPRVML SERIES DIFFUSERS.
13. INSTALL THE DESIRED LAMP (BY OTHERS)
INSTRUCTIONS FOR LAMP POSITIONING
THERE ARE 3 LAMP POSITIONS AVAILABLE FOR
THIS FIXTURE. THE FIXTURE IS SHIPPED AND
INSTALLED IN THE LOWEST (CLOSEST TO
REFLECTOR APERTURE) POSITION.THESE
POSITIONS ARE DETERMINED BY AN
ADJUSTABLE BRACKET MECHANISM WITHIN THE
HOUSING. THE 57W VERSION ONLY HAS ONE
LAMP POSITION AVAILABLE.
14a. IF THE LAMP IS A 26W COMPACT FLUORESCENT,
DO NOT REPOSITION THE LAMP.
14b. IF THE LAMP IS A 32W COMPACT FLUORESCENT
LAMP, PLACE THUMBS AT BOTTOM OF LAMP AND
PUSH UP UNTIL BRACKET MECHANISM CLICKS
INTO MIDDLE POSITION.
14c. IF THE LAMP IS A 42W COMPACT FLUORESCENT
LAMP, PLACE THUMBS AT BOTTOM OF LAMP AND
PUSH UP UNTIL BRACKET MECHANISM CLICKS
INTO TOP POSITION.
15. TO REPOSITION THE LAMP TO A LOWER
POSITION, PULL DOWN ON THE CHAIN SHOWN
IN THE LOWER FIGURE. PUSH ON LAMP UNTIL IT
IS IN THE NEW POSITION (SEE STEPS 14a - 14c).
9.
HOLD PENDANT UP TO HOUSING FIXTURE,
ALLOWING CEILING COVER TO REST AT BOTTOM
OF STEM. CONNECT THE MATE-N-LOCK
CONNECTOR FROM THE HOUSING FIXTURE TO
THE CONNECTOR FROM THE PENDANT.
10. PASS MATED CONNECTORS THROUGH SLOT OF
PENDANT BRACKET AND ALIGN HOLES OF
MOUNTING PLATE TO HEX SCREWS ON
PENDANT BRACKET. TURN MOUNTING PLATE
COUNTERCLOCKWISE AND TIGHTEN HEX
SCREWS.
11. MATE CEILING COVER TO HOUSING FIXTURE
HOLE AND INSERT TORSION SPRINGS THROUGH
SLOTS (SEE DETAIL “B”).
TORSION
SPRING
REFLECTOR NOT SHOWN FOR
EASE OF VIEW
CHAIN
SEE PAGE 3 FOR FIGURE OF FULLY INSTALLED FIXTURE
SLOT FOR TORSION
SPRING (2X)
CEILING
COVER
DETAIL “B”
(FOR STEP #11)
RETAINER
RING
STEM AND
PENDANT
COVER
PLATE
BALL HALF