INSTALLATION INSTRUCTIONS
SCIBX8
THIS UNIT IS TO BE USED ONLY IN SLOPED CEILINGS FROM 2-12 TO 12-12 PITCH.
THIS UNIT IS ONLY TO BE MOUNTED WITH JUNCTION BOX SLOPED DOWN (AS SHOWN IN FIG. 2).
IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information
and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,
and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and
during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by
qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.
Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in
compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by
the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from
product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or
the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.
*********************************************************************************************************************************************************
WARNING: Thermal insulation may be installed in direct contact with fixture, but DO NOT install insulation in excess of eight (8) inch-
es deep above fixture. Greater depth may cause the thermal protector unit to cycle the fixture on or off.
WARNING: Use only those trims, lamps and maximum wattages proper for this fixture, as indicated on the label within the fixture
housing.
WARNING: The National Electrical Code, Article 110-3 (b), states that "Listed or labeled equipment shall be used or installed in accor-
dance with any instructions included in the listing or labeling". Use only with Prescolite UL listed trims. Use of other trims not listed in
this fixture, including those that are UL classified, is a violation of N.E.C. 110-3(b) and voids all warranties.
WARNING: If any special control devices are used with this fixture, follow the instructions carefully to assure full compliance with
N.E.C. requirements. If there are any questions, contact a qualified electrical contractor.
*********************************************************************************************************************************************************
2
3
21
7
22
9
1
4
3
9
10
4
3
17
1
5
20
3
2
6
23
24
10
7
23
6
8
19
18
3
11
13
16
15
FIG. 1
“A-A”
FIG. 3
“A”
“A”
FIG. 2
FIG. 5
*
Always install with J-Box
in elevated position as displayed
to ensure proper position.
G6 Gasket
(Purchase
Separately)