Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .06268800

Instruction

Sheet

PLUG-
BALLAST

WARNING:

CAP OFF

UNUSED 120V OR 347V
LINE

GREEN GROUND

BLACK LINE
(120V OR 277)

CONNECT 277V TO TP OR
120V TO TP DEPENDING ON
SUPPLY

WIRE DIAGRAM 120V WITH 347V

WHITE COMMON

GREEN GROUND
WHITE COMMON
BLACK LINE (120)
ORANGE LINE (347v)

WIRE DIAGRAM 120V WITH 277V

BALLAST

BALLAST

PLUG-JBOX

PLUG-JBOX

PLUG-
BALLAST

NOTE: BE SURE TO CONNECT THE PLUG FROM THE BALLAST WITH THE PLUG FROM THE J-BOX.

TRIM INSTALLATION

920 TRIM:

1. ADJUST SOCKET BRACKET TO PROPER POSITION BY LOOSENING WING NUT.

PAR 30 LAMPS: SLIDE BRACKET TO LOWEST (TOWARDS APERTURE) POSITION.

PAR 38 LAMPS: SLIDE BRACKET TO HIGHEST (AWAY FROM APERTURE) POSITION.

2. TIGHTEN WING NUTSECURELY.

3. INSTALL TRIM BY LOCATING COIL SPRINGS IN SLOTS ON HOUSING.

4.INSTALL LAMP.

832, 833 AND 834 TRIMS:

1. ADJUST SOCKET BRACKET TO PROPER POSITION BY LOOSENING WING NUT.

PAR 30 LAMPS: SLIDE BRACKET TO LOWEST (TOWARDS APERTURE) POSITION.

PAR 38 LAMPS: SLIDE BRACKET TO HIGHEST (AWAY FROM APERTURE) POSITION.

2. TIGHTEN WING NUTSECURELY.

3. INSTALL LAMP.

4. LOCATE TRIM CLIP RETAINING HOLES ON LIP OF PLASTER FLANGE. ATTACH TRIM

RETAINING CLIPS (3) TO PLASTER FLANGE.

5. PRESS TRIM INTO APERTURE.

JBOX