Maestro settings limitations, Mini maestro serial baud rate limitations, Section 9 – Pololu Maestro User Manual
Page 70

9. Maestro Settings Limitations
Mini Maestro serial baud rate limitations
On the Mini Maestro 12, 18, and 24, the following baud rates should not be exceeded, or the processor may become
overloaded, causing degraded performance.
10–100 Hz 111–250 Hz
333 Hz
Serial mode: UART/USB chained*
200 kbps
115.2 kbps 115.2 kbps
Serial mode: Dual-port
115.2 kbps
57.6 kbps
57.6 kbps
* Assuming bytes are not sent and received simultaneously, as required for the Pololu protocol.
Micro Maestro pulse length limitations (high pulse rates only).
Most servos are designed for 50 Hz operation. Unless you know that you need high pulse rates, you
can safely ignore this section.
The Micro Maestro has a restricted maximum pulse length for pulse rates of 67 Hz and higher. The restriction depends
on the Servos available setting and is enforced automatically by the Maestro Control Center.
The maximum pulse lengths in microseconds are given below:
6 servos 5 servos 4 servos 1–3 servos
67 Hz
2448
2944
3000+
3000+
71 Hz
2272
2736
3000+
3000+
77 Hz
2112
2544
3000+
3000+
83 Hz
1936
2336
2944
3000+
91 Hz
1776
2144
2688
3000+
100 Hz
1616
1936
2448
3000+
Mini Maestro servo pulse length limitations (high pulse rates only)
Most servos are designed for 50 Hz operation. Unless you know that you need high pulse rates, you
can safely ignore this section.
On the Mini Maestro 12, 18, and 24, pulse rates of 200–333 Hz put restrictions on the servo pulse lengths. These
restrictions apply to all servo channels, even if some are set to a lower pulse rate using the Period multiplier feature.
The following tables show allowed minimum and maximum pulse lengths, in microseconds, for a variety of
combinations of pulse rates and servo numbers. All enabled servos must always satisfy the restrictions on some table
row, so the easiest way to follow the restrictions is to pick a row, then configure minimums and maximums for
specific channels according to the restrictions given in that row. However, you do not need to specify the ranges of
your servos in advance: you can switch some channels off or adjust their positions to access a wider range on other
Pololu Maestro Servo Controller User's Guide
© 2001–2014 Pololu Corporation
9. Maestro Settings Limitations