4.1 Standard equipment of VO ovens (basic variation)

• Electronic fuzzy-supported PID process controller with permanent power matching and time-saving

auto-diagnostic system for rapid fault finding (see section: “Error messages”)

• Language

selection

• Alphanumeric text display
• Internal log memory with 1024 kB for storing actual temperature, temperature setpoint, vacuum and

error states with time stamp

• Control of oven and logging of actual temperature values on MEMoryCard XL
• Programme sequence control for up to 40 ramp segments
• Vacuum pressure control for digital operation of the built-in solenoid valves
• Programmable inlet valves for fresh air and inert gas
• Integrated weekly programmer with group function (e.g. all workdays)
• Recessing push/turn control for simple operation of the oven
• Visual alarm indication
• Built-in sounder as alarm if limit values are crossed, as acoustic signal at programme end and to

acknowledge input (key click)

• Digital monitor controller for overtemperature, undertemperature and automatic setpoint-following

monitor (ASF)

• Mechanical temperature limiter (TB protection class 1)
• Monitor relay to switch off heating in case of fault
• Each thermoshelf has a separate Pt100 DIN class A temperature sensor for temperature measurement

and can be removed individually

• Convenient integral 3-point temperature and vacuum calibration
• Temperature-dependent control unit ventilation
• USB interface for computer-based temperature control programmes and to read out the controller’s

internal log memory

• MEMMERT software “Celsius” for remote operation of the oven via computer and for reading the

controller’s internal log memory

• A pre-formatted blank MEMoryCard XL with 32 kByte storage capacity, reprogrammable for up to 40

ramp segments and additionally 270 hours log memory with a scanning interval of one minute

Optionally available additional fittings:
• 24 volt control output for purging and switching off external vacuum pump
• Number of flange sockets (inserts) for thermoshelves: 3 instead of 2 (VO 200) or 4 instead of 2

(VO 400-500)

• Number of thermoshelves: 2 instead of 1 (VO 400-500)
• Connection of inert gas switchover via solenoid valve
• Interface for control of optional pump module
• Drip

tray

• USB printer port
• Base
• Pump

module

• USB

cable

• External card reader for MEMoryCard XL for connection to USB interface
• Printer cable (parallel, shielded) 25-pin.
Descriptions in this manual referring to these optional additional fittings are only relevant for ovens of the
corresponding version.