2 table of attributes, Table of attributes, 7parameter reference – Lenze E84Dxxxxx User Manual
Page 65

Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05
65
7
Parameter reference
7.2
Table of attributes
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.2
Table of attributes
The table of attributes contains information which is required for communicating with the
controller via parameters.
How to read the table of attributes:
Note!
Safety-relevant parameters with write access can only be transmitted to the drive-based
safety system by safe parameter setting with the »Engineer«.
Column
Meaning
Entry
Code
Parameter name
Cxxxxx
Name
Parameter short text (display text)
Text
Index
dec
Index under which the parameter is addressed
The subindex of array variables corresponds to the
Lenze subcode number.
24575 - Lenze code number
Is only required for access via a bus
system.
hex
5FFF
h
- Lenze code number
Data
DS
Data structure
E
Single variable
(only one parameter element)
A
Array variable
(several parameter elements)
DA
Number of array elements (subcodes)
Number
DT
Data type
BITFIELD_8
1 byte bit-coded
BITFIELD_16
2 byte bit coded
BITFIELD_32
4 bytes bit-coded
INTEGER_8
1 byte with sign
INTEGER_16
2 bytes with sign
INTEGER_32
4 bytes with sign
UNSIGNED_8
1 byte without sign
UNSIGNED_16
2 bytes without sign
UNSIGNED_32
4 bytes without sign
VISIBLE_STRING
ASCII string
Factor
Factor for data transmission via a bus system,
depending on the number of decimal positions
Factor
1 ≡ no decimal positions
10 ≡ 1 decimal position
100 ≡ 2 decimal positions
1000 ≡ 3 decimal positions
Access
R
Read access
Reading allowed
W
Write access
Writing permitted (by safe parameter setting with the »Engineer«)
CINH
Controller inhibit required
Writing is only possible when the controller is inhibited
Code
Name
Index
Data
Access
dec
hex
DS
DA
Data type
Factor
R
W
CINH
Status of safety functions
9575
2567
E
1
BITFIELD_32
Command status
9572
2564
E
1
UNSIGNED_16
1
Parameter set status
9565
255D
E
1
UNSIGNED_8
1
Parameter CRC
9564
255C
A
2
UNSIGNED_32
1
Parameter set creation time
9562
255A
E
1
UNSIGNED_64
1
Time of RTC parameter setting
9561
2559
E
1
VISIBLE_STRING
Time of sec. parameter setting
9560
2558
E
1
UNSIGNED_32
1
Parameter set version
9559
2557
E
1
UNSIGNED_8
1
Stored module ID
9558
2556
E
1
UNSIGNED_16
1
SD-In Sensor type
9545
2549
A
2
UNSIGNED_8
1
SD-In Sensor function
9544
2548
A
2
UNSIGNED_8
1