C15040 | input image, 7parameter reference – Lenze E84Dxxxxx User Manual
Page 56
7
Parameter reference
7.1
Parameter list | C15040
56
Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C15040
C15051
Parameter | Name:
C15040 | Input image
Data type: BITFIELD_32
Index: 9535
d
= 253F
h
Input image of the external inputs of the drive-based safety system, displayed according to channels.
Display range
(min. hex value | max. hex value)
Value is bit-coded:
Information
Bit 0 SD-In1 channel A
Bit 1 SD-In1 channel B
Bit 2 SD-In2 channel A
Bit 3 SD-In2 channel B
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Bit 16 AIE
AIE input (error acknowledgement)
Bit 17 AIS
AIS input (restart acknowledgement)
Bit 18 Module switch
Bit 19 Reserved
Bit 20 Reserved
Bit 21 Reserved
Bit 22 Reserved
Bit 23 Reserved
Bit 24 Reserved
Bit 25 Reserved
Bit 26 Reserved
Bit 27 Reserved
Bit 28 Reserved
Bit 29 Reserved
Bit 30 Reserved
Bit 31 Reserved
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C15051 | C15051
Data type: BITFIELD_32
Index: 9524
d
= 2534
h
This code is for device-internal use only and must not be written to by the user!