2 read safe data from device, Read safe data from device, 6safe parameter transfer – Lenze E84Dxxxxx User Manual
Page 46

6
Safe parameter transfer
6.2
Read safe data from device
46
Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.2
Read safe data from device
How to read the parameter set from the device:
1. Unless there is an online connection, establish an online connection to the device.
2. Go to the Safe transfer dialog box and click Upload.
• A confirmation prompt appears asking whether the parameter is really to be uploaded
from the device.
3. Answer the confirmation prompt with Yes to continue the action.
If you are not yet registered as a user, first the Password entry dialog box is displayed.
4. Enter the device password and confirm with OK.
• Unless an individual password has been defined, enter the standard password "Lenze
SM301".
• After the password has been entered, you are registered as a user for a time period of 30
minutes. Within this period, the password does not need to be entered again for calling
a password-protected function if the online connection to the device remains
established without any interruptions.
After the registration, the parameter set is uploaded from the device, and a status message
displays whether the action was successful.
5. Confirm the status message with OK.
Note!
After the parameter set has been transmitted, make a check of the item designation and
a check/acceptance of the safety functions!
Detailed information on the check/acceptance can be found in the manual for drive
based safety of the 8400 protec series.
Note!
This function serves to overwrite the parameter settings in the »Engineer« with the
current settings of the drive-based safety system!
Only a valid parameter set can be read back from the drive-based safety system.