3.6.1.1
PROFIsafe output data
The PROFIsafe output data (control data) is transmitted from the control to the drive-based safety
system.
Control byte
For the PROFIsafe V1 mode only the indicated bits of the PROFIsafe control byte are supported:
[3-1]
Structure of the PROFIsafe control byte in V1 mode
[3-2]
Detailed specification of the control byte in V1 mode
For the PROFIsafe V2 mode only the indicated bits of the PROFIsafe control byte are supported:
[3-3]
Structure of the PROFIsafe control byte in V2 mode
[3-4]
Detailed specification of the control byte in V2 mode
Bit
Name
Value
Meaning
0 STO
0
The STO function is activated.
1 SS1
0
The SS1 function is activated.
9 ES
1
Confirmation is active:
During special operation motion functions are possible.
11 OMS
0
Normal operation
1
Special operation
16 PS_AIS
01
Activate restart acknowledgement.
The bit must be set for at least one PROFIsafe cycle.
17 PS_AIE
01
Activation of error acknowledgement.
The bit must be set for at least one PROFIsafe cycle.
23 SSE
0
The SSE function is activated.
Unlisted bits are reserved for future extensions and must be transmitted with "0"!
Assignment
Bit
Byte
7
6
5
4
3
2
1
0
4
-
-
-
activate_FV
-
-
-
-
Bit coding of control byte
Bit
Name
Value
Meaning
4 activate_FV
1
The PROFIsafe output data is passivated.
-
0
Reserved for future extensions.
Assignment
Bit
Byte
7
6
5
4
3
2
1
0
4
-
-
Toggle_h
activate_FV
-
R_cons_nr
-
-
Bit coding of control byte
Bit
Name
Value
Meaning
2 R_cons_nr
1
Reset of the consecutive number.
4 activate_FV
1
The PROFIsafe output data is passivated.
5 Toggle_h
1/0
Change increases the consecutive number.
-
0
Reserved for future extensions.