C15013 | parameter set creation time, C15014 | time of rtc parameter setting, C15015 | time of sec. parameter setting – Lenze E84Dxxxxx User Manual
Page 53: C15016 | parameter set version, C15017 | stored module id, C15016, 7parameter reference

Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05
53
7
Parameter reference
7.1
Parameter list | C15013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C15013
C15014
C15015
C15016
C15017
Parameter | Name:
C15013 | Parameter set creation time
Data type: UNSIGNED_64
Index: 9562
d
= 255A
h
Time of parameter set creation
Display range
(min. value | unit | max. value)
0
18446744073709552000
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C15014 | Time of RTC parameter setting
Data type: VISIBLE_STRING
Index: 9561
d
= 2559
h
Time of acceptance of the parameter set from the memory module as value of the real-time (RTC).
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C15015 | Time of sec. parameter setting
Data type: UNSIGNED_32
Index: 9560
d
= 2558
h
Time of acceptance of the parameter set from the memory module as value of the power-on time meter from the
controller
Display range
(min. value | unit | max. value)
0
s
4294967295
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C15016 | Parameter set version
Data type: UNSIGNED_8
Index: 9559
d
= 2557
h
Display of the parameter set version available in the drive-based safety system.
Selection list
(read only)
0 No current parameter set
1 Parameter set V1.0
2 Parameter set V1.1
3 Parameter set V1.2
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C15017 | Stored module ID
Data type: UNSIGNED_16
Index: 9558
d
= 2556
h
Display range
(min. value | unit | max. value)
0
65535
Read access Write access CINH PLC STOP No transfer Scaling factor: 1