6
Safe parameter transfer
44
Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6
Safe parameter transfer
The functions for a safe parameter transfer are
available in the Safe transfer dialog box.
The Safe transfer dialog box is opened via the Safe
transfer button on the Safe configuration tab.
By clicking the More >> button in the Safe transfer
dialog box, the functions for password
management and general reset are displayed in
addition.
A renewed click on the button now labelled with
<< Reduce hides these functions again.
Note!
To execute the functions for a safe parameter transfer, you have to enter a device
password!
When the memory module is used for the first time together with the drive-based safety
system, the required password file for the safe parameter transfer is not yet available in
the memory module and the error message "Reading of the password file failed" is
displayed. In this case a general reset of the device is required!
With a general reset, the safe parameter set is deleted in the memory module and in the
drive-based safety system and the required password file is created in the memory
module. After this, the drive-based safety system must be re-parameterised.