Safe configuration
3.5
Safety functions
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.5.1.3
Emergency stop function (SSE)
3.5.1.4
Safe torque off (STO)
Safe Stop Emergency / SSE
Description
The emergency stop function starts
, depending on the setting of the "emergency stop
function" parameter.
• In special operation the emergency stop cannot be avoided.
• Connect the emergency stop buttons, which must not be overruled by a special operation, to
the emergency stop function. For this purpose, parameterise the safe input as "emergency
stop" (
Parameter
SSE: Emergency stop function
• Selection of the function to be performed (
Activation
How to activate the function:
• A data telegram with a corresponding content is sent to the controller via the safety bus.
• "OFF state" at a safe input which has been assigned to the function by parameter setting.
Safe torque off / STO (corresponds to a "Stop 0" according to EN 60204)
Description
By using this function the power supply for the motor is safely interrupted immediately. The
motor cannot generate a torque and thus no dangerous motions of the drive.
• Additional measures are required against movements caused by external forces, e.g.
mechanical brakes.
• The restart behaviour can be set.
Priority
Priority function: none
Subordinated function:
Function
Parameter
Function sequence and error response have no adjustable parameters.
Activation
How to activate the function:
• A data telegram with a corresponding content is sent to the controller via the safety bus.
• "OFF state" at a safe input which has been assigned to the function by parameter setting.
• As response to the error stop request.
• As response to the emergency stop request.
n
t
0
STO