beautypg.com

3 emergency stop function (sse), 4 safe torque off (sto), Emergency stop function (sse) – Lenze E84Dxxxxx User Manual

Page 29: Safe torque off (sto), Rised function, 3safe configuration

background image

Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05

29

3

Safe configuration

3.5

Safety functions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.5.1.3

Emergency stop function (SSE)

3.5.1.4

Safe torque off (STO)

Safe Stop Emergency / SSE
Description

The emergency stop function starts

STO

or

SS1

, depending on the setting of the "emergency stop

function" parameter.

• In special operation the emergency stop cannot be avoided.

• Connect the emergency stop buttons, which must not be overruled by a special operation, to

the emergency stop function. For this purpose, parameterise the safe input as "emergency

stop" (

C15031

).

Parameter

C15205

SSE: Emergency stop function

• Selection of the function to be performed (

STO

or

SS1

).

Activation

How to activate the function:

• A data telegram with a corresponding content is sent to the controller via the safety bus.

Safety bus ( 33)

• "OFF state" at a safe input which has been assigned to the function by parameter setting.

Safe inputs ( 42)

Safe torque off / STO (corresponds to a "Stop 0" according to EN 60204)
Description

By using this function the power supply for the motor is safely interrupted immediately. The

motor cannot generate a torque and thus no dangerous motions of the drive.

• Additional measures are required against movements caused by external forces, e.g.

mechanical brakes.

• The restart behaviour can be set.

Restart behaviour ( 28)

Priority

Priority function: none

Subordinated function:

SS1

Function

Parameter

Function sequence and error response have no adjustable parameters.

Activation

How to activate the function:

• A data telegram with a corresponding content is sent to the controller via the safety bus.

Safety bus ( 33)

• "OFF state" at a safe input which has been assigned to the function by parameter setting.

Safe inputs ( 42)

• As response to the error stop request.

• As response to the emergency stop request.

n

t

0

STO