7.6 Indexer Program

This will select MotionView Studio section of the MotionView software. Right panel is used to enter,
edit and debug User Programs. Menu and toolbar will display additional features needed for program
preparation compiling debugging and loading to the SSi’s memory. Motion View Studio tools and
operations are described in details in Programmer’s Manual.

7.7 Security

This option will protect source code of the User Program with password. If password was set then SSi
will ask for password before displaying User Program text. Password can be any alphanumeric string.

7.8 Faults Group


Faults Group loads fault history from the drive. New faults replace oldest faults in circular manner. In
any case fault # 0 is the most recent fault. To clear fault history from the drive’s memory click on
“Reset Fault history” button. Each fault has its code and explanation of the fault.

7.9 Tools

7.9.1 Drive

monitor


Drive monitor shows you motor hall sensors’ states and actual motor encoder counts.
This tool is useful when troubleshooting motor encoder’s connections.

7.9.2 Oscilloscope

tool


Oscilloscope tool gives real time representation of different signals inside SSi drive and is helpful when
debugging and tuning drives. Operation of oscilloscope tool described in MotionView software’s User’s
Manual. Below given the list of the signals you can observe with oscilloscope tool:

Phase Current (RMS):

Motor phase current

Phase Current (Peak):

Motor peak current

Iq Current :

Measures the motor Iq (torque producing) current

Motor Velocity:

Actual motor speed in RPM

Commanded Velocity:

Desired motor speed in RPM (velocity mode only)

Velocity Error:

Difference in RPM between actual and commanded motor velocities.

Position Error:

Difference between actual and commanded position

(Step & Direction mode only)
Commanded position:

Target (theoretical) position. SSi drives only

Actual position:

Actual shaft position. SSi drives only

Note
If the drive filter is configured for PIVFF mode, Commanded Velocity is not available

since commanded velocity is not calculated directly in this mode. If this signal is selected it
will show 0 RPM and Velocity Error will show Motor Velocity if selected as source.