Lenze−codestellen und canopen−objekte – Lenze EMF2181IB User Manual
Page 62

Lenze−Codestellen und CANopen−Objekte
Description of the codes relevant for the modem
l
62
EDSMF2181IB EN 3.0
C1206:
Modem initialisation
Code
C1206
Name
Modem initialisation
Index: 0x5B49 (23369)
Subcode
Lenze
Values
Access
Data type
AT&FE1QØ&K3&
D2&C1
rw
VS
¨ RSP þ PS transfer
¨ CANopen:
)
Note!
In most cases, the use of the Lenze setting is sufficient for initialising the
modem.
However, if it is not possible to establish a connection, there is the possibility
of adapting the initialisation command via the applicable AT commands.
Only change the value of this code if you are absolutely sure that it is
necessary!
An incorrect initialisation command may make another dialup process
impossible. In this case you have to load the Lenze setting of the modem and
correct the AT commands entered before.
With code C1206, the internal or external modem receives an initialisation command that
in most cases consists of several AT commands.
)
Note!
Changes to this code only become effective if the mains is switched again, or
by a modem reset (code C1226).
I
Tip!
For the ModemCAN 2181 communication module, a part of the whole amount
of commands is represented in the annex of these instructions.
C1207:
Switch−over of internal / external modem
Code
C1207
Name
Switch−over of internal / external modem
Index: 0x5B48 (23368)
Subcode
Lenze
Values
Access
Data type
0
0, 1
rw
FIX32
¨ RSP þ PS transfer
¨ CANopen:
Using code C1207, a switch−over from the internal to the external modem can be effected.
This code can only be written to via CAN.
)
Note!
Changes to this code only become effective if the mains is switched again, or
by a modem reset (code C1226).