Installation

Electrical installation
Communication via the diagnostic interface (9400)

5

l

22

EDSMF2181IB EN 3.0

5.2.3

Communication via the diagnostic interface (9400)

2181FEW007

Fig. 5−4

Communication via the diagnostic interface (only 9400)

Installation steps

Step

Action

Connection

(see graphics)

Additional
information

1.

Connect voltage supply to the plug connector

7

^ 23

2.

Connect diagnostic interface to the 9400 inverter (use
pre−assembled cable)

5

^ 30

3.

If it’s not possible to use the internal modem, connect an
external modem.

8

^ 28

4.

Connect inverter to CAN bus

;

5.

Connect ModemCAN 2181 to telephone network

4

^ 29

We especially recommend carrying out communication via the diagnostic interface if the
2181 communication module is only connected temporarily.

In the case of a fixed installation, communication via CAN is preferable, see (

21).