Commissioning

Configuring the communication module

6

l

36

EDSMF2181IB EN 3.0

Now a first selection of the communication module from the telephone directory can be
made.

1. For this purpose, click the "Connect" button. Check the values listed and select

"Connect" again.

2. Now a selection and user authentication are carried out.

3. After successful dial−up it is determined whether the CAN parameters configured on

the PC are identical to those in the device. If this is not the case, they are adjusted.

4. Then a small status window appears, showing the connection status and the

connection time. Via this window, the connection can also be disconnected again.

5. Change to the system bus configurator again, select the "General" tab and click the

"Diagnostics" tab. Now the CAN bus can be searched for nodes connected.

6. Confirm the confirmation prompt with "Yes", or select "No" to abort the diagnostics

process.

When the communication module has succeeded in communicating with the
corresponding bus nodes, the system bus node addresses of the bus nodes found are listed
in the "Device status" field.

If the communication module is not able to communicate with the bus nodes, an error
message is displayed.

The communication module answers with its CAN address or with "0" if it has no address
(depending on C00350 and C1213). The data telegrams for communication with the
communication module itself, however, are not visible on the CAN bus.

)

Note!

Additional information about the configuration of the communication module
can be found in the online help of the system bus configurator.