l

12

EDSMF2181IB EN 3.0

LED status displays

Pos.

Colour

State

Description

0

(M)

yellow

on

The ModemCAN 2181 is ready for operation.

blinking

Active communication over the telephone network

1

(E)

red

on

l

Operation via the diagnostic interface:
No device is connected to the diagnostic interface.

see

^ 40

l

Operation via CAN:
ERR LED

2

(R)

green

on

l

Operation via the diagnostic interface:
A device is connected to the diagnostic interface.

see

^ 40

l

Operation via CAN:
RUN−LED

3

(P)

green

on

The ModemCAN 2181 is supplied with voltage.

)

Note!

Refer to the instructions on the signals provided by the ERROR LED and RUN
LED in the Troubleshooting chapter (