Profinet: stack init error [0x01bc6534, Profinet: internal error [0x01bc6650, And the error message – Lenze E84DGFCR User Manual
Page 72: Profinet: stack init error, 0x01bc6534, 0x01bc6650, Communication manual 8400 motec profinet

Communication manual 8400 motec PROFINET
Error messages
Possible causes and remedies
72
L
EDS84DMOTPNET EN 2.0 - 11/2011
PROFINET: Stack init error [0x01bc6534]
PROFINET: Internal error [0x01bc6650]
Response (Lenze setting printed in bold)
Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The stack cannot be initialised with the parameters
selected by the user. This may be due to a station name
which does not comply with the PROFINET specification.
Check and, if necessary, adapt PROFINET parameters:
Setting the IP configuration ( 30)
Setting the station name ( 28)
Response (Lenze setting printed in bold)
Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Device is damaged.
Send device with error description to Lenze.