6 identify, Identify, E84aycib communication manual (interbus) – Lenze E84AYCIB User Manual
Page 51
EDS84AYCIB EN 4.0 - 11/2010
L
51
E84AYCIB communication manual (INTERBUS)
Parameter data transfer
Supported PMS services
9.3.6
Identify
The "Identify" PMS service provides information on how to identify the controller.
The controller with the plugged-on communication module provides the following
parameters for this:
Example: Visible string "device type" (15 characters)
Structure of the visible string "device version" (15 characters)
Parameter
Type
Description
Device manufacturer
Visible string
Company name "Lenze"
Device type
Visible-string (15 characters) Device name for the controller and the
communication module
Device version
Visible-string (15 characters) Firmware version of the controller and the
communication module
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
E
8
4
A
F
G
H
C
A
F
Y
I
B
Character
Description
1 ... 3
Product range of the controller and the communication module (E84 = 8400 series)
4
Blank
5 ... 6
A: Version of the controller
F: Firmware of the controller
7 ... 9
G: Device / controller
SC: StateLine C
HC: HighLine C
10
Blank
11 ... 12
A: Version of the communication module
F: Firmware of the communication module
13 ... 15
Y: Communication module
IB: INTERBUS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
4
.
0
0
0
1
.
0
0
Character
Description
1 ... 5
Firmware version of the controller (from C00099/0, e.g. "04.00.xx.yy", without internal revision
status ["xx"] and build status ["yy"])
6
Blank
7 ... 11
Firmware version of the communication module (from
, e.g. "01.00.xx.yy", without internal
revision status ["xx"] and build status ["yy"])
12 ... 15
Blank