beautypg.com

Intelix ASW-WP Installation Manual User Manual

Page 22

background image

ASW-WP Installation Guide

12. Connect the ASW-WP to an HDBaseT receiver

with an RS232 port (DIGI-HD60C-R) and

power the devices.

13. Connect your PC COM port to the RS232 port

on the HDBaseT receiver. See p. 14 for more

information on RS232 connections.

14. Press the “Program” button, confirm

the action, and wait for the upload to

finish. The unit is now programmed,

and the Display Control feature is

activated. To disable Display Control -

you will need to send the “Display

Control Off” command via a terminal

program.

15. Disconnect the serial cable from your

PC and connect it to the RS232 port on

the display.

16. To program multiple ASW-WP devices, repeat

steps 12-15 for each unit.

22