Intelix ASW-WP Version Log User Manual
Intelix Hardware
Hardware/Firmware Version Log
Product: ASW-WP
Manufacturer: Intelix
HW Version FW Version Release Date
Notes
1.0
6.0
July 10, 2013
Production Release
1.0
7.4
April 10, 2014 • The audio receivers that were having issues decoding the
VGA audio should now decode (this is yet to be verified).
• When the unit powers up from Standby using a VGA
laptop, the signal is transmitted on the CAT5.
• HDMI Sources will drop the Video Signal when the unit
goes into Standby or is powered down
• Faster Switching and response time to the user.
• The timers are more reliable.
• The wakeup time from an HDMI source will take about 3
seconds.
• EDID will be read properly every time by the source on
unit power up, on Wakeup from standby and on
unplugging and plugging in of the source cable.
• The unit will not go to standby, ever, based on No
Activity. It will still go to standby within 30 minutes of no
signal detection.
• HDMI will wake up the unit even when a VGA source is
plugged in.
• If there is no monitor connected in EDID pass through
mode, the sources will read a default resolution of
1024x768.
• When the unit wakes up from Standby it will switch over
to the input that resulted in the wake up.
• The VGA signal will not drop out when the HDMI signal is
removed.
• Occasional issue where VGA image is shifted to the left is
rectified.
1.0
8.0
June 27, 2014 • VGA Audio should work with all displays, audio receivers
and projectors. The issue was in the audio infoframe
information being sent to the sink device.
• All Displays will display the proper resolution when
presenting a 1080p picture from the VGA input. The
issue was the use of 1080i timing instead of the proper
1080p timing information