INFICON DataFID Portable Flame Ionization Detector for Leak Detection and Repair (LDAR) User Manual
Page 53
074-578-P1A
53
Method 21 routing information can be added or subtracted from the file as necessary.
Upload Location Route Entry from PC
1) Single Location Route Entry Description
A single Location Route list entry will take place in the following manner:
<locroute> <list#> <
”Location description” > <CR>
where:
a) locroute = keyword that must appear at the start of every line in order for DataFID to
recognize an entry.
b) list# = Location Route number in the list.
c)
”Location description” = 21 character (max) Location description that must be surrounded
by quotes (" ").
d) CR LF
= Carriage Return and Line Feed are accomplished by pressing the ‘Enter’ key at the
end of each line.
NOTE: <> are used as separators and are NOT included in the text file.