E T C I n s t a l l a t i o n G u i d e

Right I/O Card Upgrade

Right I/O Card Upgrade Kit Installation

Page 4 of 4

Electronic Theatre Controls, Inc.

Step 6:

Replace the dimmer modules, Station Power Module and Architectural Control Processor
into the slots they were previously removed.

Step 7:

Slide the module retention bar to the right and tighten the screws to secure it in place.

Step 8:

Supply power to the DRd enclosure.

Step 9:

Unless structural changes are being made to the existing system, no dimming or
architectural re-configuration should be necessary. If the system is being modified,
reference the related Architectural Control Processor Configuration and Programming
Guide for configuration setup and operation information.

W A R N I N G :

Never power up or operate the Unison DRd enclosure without all modules

installed. Failure to comply exposes you to dangerously high voltages that may

result in death by electrical shock.