Install the new i/o card, Right i/o card upgrade, N o t e – ETC Unison DRd Right IO Card Upgrade Kit User Manual
Page 3
E T C I n s t a l l a t i o n G u i d e
Right I/O Card Upgrade
Right I/O Card Upgrade Kit Installation
Page 3 of 4
Electronic Theatre Controls, Inc.
Install the new I/O Card
Step 1:
Gently slide the new right I/O card edge connector into the receptacle on the signal
distribution board. Make certain each pin is aligned to its correct receptacle.
Step 2:
Secure the right I/O card in place using four of the screws provided in this upgrade kit.
Step 4:
Locate the DMX termination switches on the right I/O card. Terminate them to the correct
setting based on your installation. You may refer to the old right I/O card to determine the
previous DMX termination settings.
• Source - reserved for future development
• Off - no termination, DMX will pass by this device to the next DMX device in the data
run
• End - termination is on. Used for the last DMX device (e.g. DRd enclosure) that is
physically connected in the daisy-chained DMX In data run.
Step 5:
Reinstall the option card (if used).
a: Align the option card to the mounting studs in the bottom right side of the enclosure.
• Notice the mounting holes on the option card. One is a slotted keyhole, another is
an open ended slot, and the remaining two on the other end of the board are
standard mounting holes used to secure the card in place.
b: Set the rear left stud through the slotted keyhole and align the open ended slot with the
back right side mounting stud.
c: Gently slide the option card toward the right I/O card, aligning the card edge connector to
the receptacle on the right I/O card. Make certain each pin is aligned to its correct
receptacle.
d: Secure the bottom two mounting studs with the screws previously removed.
e: Check each pluggable connector on the option card to ensure it is fully seated.
N o t e :
When reconnecting DMX, be sure each connector is replaced to the correct
receptacle. DMX A is the top receptacle, DMX Pass-Thru is the middle receptacle, and
DMX B is the bottom receptacle.
S
IGNAL
D
ISTRO
R
IDE
T
HRU
/B
ATT
J9
DUAL RACKS
LPS
APM
DMXB
AUX POWER
LON LINK / ECHO BUS
CDI
DMXA
B
+
B
-
COM
A
+
A
-
COM
7183B4606
REV
F
© 2013
ETC
,
INC
.
MADE
IN
THE
U
.
S
.
A
.
B
+
B
-
COM
COM
PANIC
A
+
A
-
COM
DMXB
DMXA
SRC
OFF
END
DMX P
ASS
-T
HRU
Step 3:
Reconnect all pluggable connectors to their appropriate
receptacle on the right I/O card, ensuring they are fully
seated.
The following connections are available, but may not be
used by every installation.
• Aux Power
• LON Link Power/ Echo Bus
• Ride Thru / Battery Backup
• Com / Panic
• Dual Racks (if Auxiliary rack installed)
• DMX A
• DMX Pass-Thru
• DMX B