Connect the PE to the closest ground connection near the power supply.

Connect the PR to the closest ground connection near the power supply.

Figure 19: Main Power Supply Connection Diagram

.10.9 Auxiliary Supply (optional) for Guitar

Notes for 12 ~ 195 VDC Auxiliary Supply connections:

The source of the 12 ~ 195 VDC Auxiliary Supply must be isolated from the

main.

For safety reasons, connect the return (common) of the Auxiliary Supply

source to the closest ground near to it.

Connect the cable shield to the closest ground near the Auxiliary Supply

source.

Before applying power, first verify the polarity of the connection.

7.

Caution: Power to the Guitar must come from the Main Supply and not

from the Auxiliary Supply.

Figure 20: Auxiliary Supply Connection Diagram