40
Connect the PE to the closest ground connection near the power supply.
Connect the PR to the closest ground connection near the power supply.
Figure 19: Main Power Supply Connection Diagram
.10.9 Auxiliary Supply (optional) for Guitar
Notes for 12 ~ 195 VDC Auxiliary Supply connections:
The source of the 12 ~ 195 VDC Auxiliary Supply must be isolated from the
main.
For safety reasons, connect the return (common) of the Auxiliary Supply
source to the closest ground near to it.
Connect the cable shield to the closest ground near the Auxiliary Supply
source.
Before applying power, first verify the polarity of the connection.
7.
Caution: Power to the Guitar must come from the Main Supply and not
from the Auxiliary Supply.
Figure 20: Auxiliary Supply Connection Diagram