9 auxiliary supply (optional) for bell, Auxiliary supply (optional) for bell – ElmoMC SimplIQ Digital Servo Drives-Guitar Evaluation Board User Guide User Manual
Page 30

Whistle, Bell Guitar Evaluation Board User Guide
Combined Evaluation Board
MAN-EVLBRD-WHI-BEL-GUI (Ver. 1.401)
30
Figure 12: Main Power Supply Connection Diagram
.9.9 Auxiliary Supply (optional) for Bell
Notes for 12 ~ 95 VDC Auxiliary Supply connections:
The source of the 12 ~ 95 VDC Auxiliary Supply must be isolated from the main
supply.
For safety reasons, connect the return (common) of the Auxiliary Supply source to
the closest ground near to it.
Connect the cable shield to the closest ground near the Auxiliary Supply
source.
Before applying power, first verify the polarity of the connection.
6.
Caution: Power to the Bell must come from the Main Supply and not from
the Auxiliary Supply.
Figure 13: Auxiliary Supply Connection Diagram