beautypg.com

Table 14. digital input parameters and values, Figure 9), Ee table 14 – Despatch Protocol Plus Controller (Heat Only) User Manual

Page 44

background image

O

PERATION

Protocol Plus Owner’s Manual

44

Version 2

Copyright © 2010 by Despatch Industries.

All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.

O


A profile must be created in the program page before trying to
run a profile number.


Table 14. Digital Input Parameters and Values.
Input 1

Input 2

Input 3

Profile Selected

ON

OFF

OFF

1

OFF

ON

OFF

2

ON

ON

OFF

3

OFF

OFF

ON

4

ON

OFF

ON

5

OFF

ON

ON

6

ON

ON

ON

7

OFF

OFF

OFF

none


· To start the selected profile, set Inputs 1, 2 and 3. Then set Input 4 to ON.

· To hold a profile, set Input 4 to OFF.

· To stop a profile, set all inputs to OFF.

Figure 9. Digital Inputs.