Control can be configured to automatically activate Manual,
Timer or Profile Mode when power is applied (power switch ON).
Refer to Section 5.5.


5.2. Manual Mode

1. Press

Select

until

Manual

displays.

O


Press
Run at any time in the procedure to activate Manual Mode.



2. Press

Menu

to display the Process Temperature Setpoint (

Setpt

). Change Setpoint

(

Setpt

) by pressing

or

.

O


If the
SPChange on the Enable page in Setup Mode has been set
to DISABLED, it must be changed to ENABLED before any
changes to the process temperature and high limit setpoints can
be made.



3. Press

Menu

a second time to display current high limit setpoint (

HLSP

). The value

can be adjusted pressing

or

. If

Band

displays, the High Limit band feature is

activated (see Control page, Section 5.6.7) and the high limit cannot be adjusted.

4. Optional feature: Press

Menu

a third time to display Event1. Press

to turn the

event ON or

to turn the even OFF. Repeat for all events which are enabled (up to

four events).

5. To start Manual Mode, press

Run

.


The display changes from

Stop

to

Run

. Return to Stopped Mode by pressing

Stop

. While

in operation, the process setpoint can be adjusted by using

or

to change the value

while the mode is running. Press

Menu

to display the High Limit Setpoint (HLSP)

setting.

O


Changes to High Limit Setpoint or Event Output Configuration
must be accomplished from the Stop Mode.