APPENDIX

178

Appendix D

Event Notification Configurations

The controller classifies disk array events into four levels depend-

ing on their severity. These include level 1: Urgent, level 2: Serious,

level 3: Warning and level 4: Information. The level 4 covers notifica-

tion events such as initialization of the controller and initiation of the

rebuilding process; Level 2 covers notification events which once have

happen; Level 3 includes events which require the issuance of warning

messages; Level 1 is the highest level, and covers events that need

immediate attention (and action) from the administrator. The following

lists sample events for each level:

Event

Level

Meaning

Action

Device Inserted

Warning

HDD inserted

Device Removed

Warning

HDD removed

Reading Error

Warning

HDD reading error

Keep Watching HDD status, may

be it caused by noise or HDD

unstable.

Writing Error

Warning

HDD writing error

Keep Watching HDD status, may

be it caused by noise or HDD

unstable.

ATA Ecc Error

Warning

HDD ECC error

Keep Watching HDD status, may

be it caused by noise or HDD

unstable.

Change ATA

Mode

Warning

HDD change ATA

mode

Check HDD connection

Time Out Error

Warning

HDD time out

Keep Watching HDD status, may

be it caused by noise or HDD

unstable.

Device Failed

Urgent

HDD failure

Replace HDD

PCI Parity Error

Serious

PCI parity error

If only happen once, it may

be caused by noise. If always

happen, please check power

supply or contact to us.

Device

Failed(SMART)

Urgent

HDD SMART failure

Replace HDD

A. Device Event