APPENDIX
172
C-3-3 Using In-band PCIe + SNMP extension agent Instal-
lation
By using the IP address assigned to the operating- RAID control-
ler using Areca SNMP extension agent through PCIe host bus
interface.
a). Set only “Community” field and keep space (or zero) on all
“SNMP Tarp IP Address“ options on the firmware-embedded SNMP
configuration function. There is no function to set other fields on
“SNMP System Configuration”.
The SNMP “Community” and “SNMP Tarp IP Address” can setup
by using browser-based manager or CLI SNMP configuration. To
launch the browser-based RAID controller SNMP function, click
on the “System Controls” link. The “System Controls” menu will
show available items. Select the “SNMP Configuration” item. The
following “SNMP System Configuration” screen is launched by
browser-based manager.
About community, Community name acts as a password to screen
accesses to the SNMP agent of a particular network device. Type
in the community names of the SNMP agent. Before access is
granted to a request station, this station must incorporate a valid
community name into its request; otherwise, the SNMP agent will
deny access to the system.
Most network devices use “public” as default of their community
names. This value is case-sensitive.
b). Mark the check box on the ‘SNMP Through PCI Inband” setting