Xit6000-ca, 3/8” tie-lok, Tool – BAND-IT XIT 6000-CA 3/8 Tie-Lok Tool User Manual
Page 34
Document # XIT177 Rev E
© Copyright
BAND-IT-IDEX, Inc. 2005
All rights reserved
www.BAND-IT-IDEX.com
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver, CO 80216-3070 USA
P: 1-800-525-0758 F: 1-800-624-3925
34
XIT6000-CA
3/8” Tie-Lok
®
Tool
Cut-off Timing Verification Procedure
1.
This procedure requires the use of the M28090 Calibration Device.
2.
This procedure requires the programmed Breakout Box to be -REV B- or later. If the
display on your tool is an earlier version, contact BAND-IT Engineering for a free
upgrade to the latest revision. See page 30, “Example of Data Output”
3.
Prepare tool by connecting the M28090 Calibration Device per instructions included
with the device.
4.
To switch the breakout box over to check cut-off timing, press and hold the reset button
on the break out box 3-4 seconds. When the button is released, the green LED will
begin flashing and the display will read “Ready to check timing: Press Trigger”
5.
Press the trigger on the XIT Tool. The breakout box will output the measured
cut-off timing.
Examples:
“Timing OK! Time = 1.01 sec”
“Warning! Time = .91 sec”
“Timing Error! Time = .80 sec”
6.
The green LED will light and remain solid if the timing is well within the
suggested range. The yellow LED will light if the timing is approaching the
limits of the suggested range; timing is OK, but may need to be adjusted soon.
The Red LED will light if the timing cycle is set too short or too long. Follow
instructions on page 29 for adjustments and re-check.
7.
Press the reset button on the XIT6000 tool and the breakout box will reset,
flashing the green LED and be ready to check the timing again.
8.
To switch from timing check mode to normal program operation, press and
hold the reset button on the breakout box for 3-4 seconds.
Note: The program will not switch into or out of timing mode unless it detects
an attached tool.
Tension Cylinder
Pressure Monitoring
System