XIT6000-CA

3/8” Tie-Lok

®

Tool

Trouble Shooting
Matrix

Symptom

Probable cause

Recommended Fix

Page

Control Module air
pressure valve is in "off"
position.

Rotate Control Module valve to open position.
Verify gauges read air pressure.

6

Pinched coil hose line

Loosen fitting on coiled hose assembly where it
enters tool body.

5

Kinked or pinched air line Remove right side handle and inspect air lines.

Remove and replace as required.

29

Tension piston
interference with hanger
screw holes.

Loosen Hanger Screw on top of tool. Thread
engagement cannot exceed .125 in.

10

Control Module air
pressure valve is in "off"
position.

Rotate Control Module valve to open position.
Verify gauges read air pressure.

6

Clamp tail inside tool

Remove clamp tail, if jammed remove
maintenance/flip cover and remove clamp
material.

15,18

Knife is in forward
position.

Remove or replace knife. Verify missing and or
damaged linkage.

22,26

Wrong clamp type for

Verify proper tool for selected clamp.

9

Handle will not

adjust

Handle nut is
damaged/misaligned.

Remove handle assembly and inspect
nut/housing for damage. Replace as required.

10

Tool will not

operate when

trigger is

depressed

Clamp will not

insert into tool

* = for additional assistance, contact BAND-IT