XIT6000-CA
3/8” Tie-Lok
®
Tool
Specifications:
•
Power: 110 VAC to 9 VDC wall supply adapter (6 ft wire provided)
•
Pressure range: will detect 25 to 125 PSI
•
Output: 9-pin RS-232 serial (approx 10 ft cable provided)
•
Serial settings:
o
2400 Baud
o
8 bit
o
No parity
o
1 stop bit
o
ASCII formatted data
o No flow control
•
Data format: Data columns (clamp number, PSI, estimated LBF and error if any)
separated by tabs, each record separated by line feed / carriage return, (hard return)
•
Data is sent at each clamp installation cycle
•
Accuracy:
o
PSI: +/- 1.0
o
LBF: +/- 15
Data Capture:
The XIT6000-CA Tension Cylinder Pressure Monitoring System can be used with many Data
Capturing Devices including any computer with Windows operating software.
•
Any properly equipped tool will work with any XIT6000 data breakout box. The tool’s
serial #, clamp count and settings remain with the tool and will be detected by
any
breakout box.
•
Any software or hardware that can read the stated format can be used to collect data as it
is sent from the tool.
(i.e. Hyper Terminal provided with Windows (Windows2000: Start – Programs –
Accessories – Communications - Hyper Terminal). In settings, use the serial
port the tool is connected to instead of a phone number. Under “Connect using:”
select the port, typically COM1 or COM2. Using settings listed under
specifications.)
•
Updates or customizations to the XIT6000-CA program can be sent to the customer using
a single executable file, no other software is required. Contact BAND-IT Engineering at 800-
525-0758.
Tension Cylinder
Pressure Monitoring
System