It1000-ab, 33 of 38, 1/4” tie-lok – BAND-IT IT1000-AB 1/4 Tie-Lok Tool User Manual

Page 33: Tool, Tension cylinder pressure monitoring system

background image

Document # I17791 Rev H

© Copyright

BAND-IT-IDEX, Inc. 2009

All rights reserved

www.BAND-IT-IDEX.com

BAND-IT-IDEX, Inc.

A Unit of IDEX Corporation

4799 Dahlia Street Denver, CO 80216-0307 USA

P: 1-800-525-0758 F: 1-800-624-3925

33 of 38

IT1000-AB

1/4” Tie-Lok

®

Tool

Data Capture:

The tension feedback system can be used with many data capturing devices including any

computer with Windows operating software.

Any properly equipped tool will work with any I75390 data control

box. The tool’s

serial #, clamp count and settings remain with the tool and will be detected by any control box
used. (*the I75390 system will not work with the X75390 system)

Any software or hardware that can read the stated format can be used to collect data as it is sent

from the tool.

• Updates or customizations to the program in the control box can be sent to the customer using a

single executable file, no other software is required.
Contact BAND-IT Engineering at 800-525-0758.

Example of Data Output:

Program: I75301 Rev A
Pressure: 55 to 75
Force: 336 to 360
Clamp #

PSI

LBF Tool # Error

30

11111

31

69.1

360 11111

32

64.8

337 11111

33

58.1 302 11111 LOW

34

72.7 378 11111 HIGH

35

69.0

359 11111 C

LBF = The calculated force applied to the clamp tail +/- 10 LBF.

One or both of the Pressure and Force rows will display, depending on control box settings. See
page XX for instructions on setting the parameters.

Clamp number 33 shows a low output and clamp number 34 shows a high output for this example.

Clamp number 35 shows the data output when the system fails to detect a complete cutoff cycle in
the time allowed. Note that having the tool on the M28090 device will trigger this error.

Clamp number 30 shows output when tool is first connected.

Incompatible tools:

In the case that the tool does not have the correct hardware installed the data control box will
output the message “Error! Incompatible tool type detected”

Contact BAND-IT for information on upgrades.

Tension Cylinder
Pressure Monitoring
System