IT1000-AB

1/4” Tie-Lok

®

Tool

Symptom

Probable cause

Recommended Fix

Page

Rear tension block slipping,
therefore tool does not
reach cut off tension.

Remove and inspect gripper block assembly. Replace as
required.

24

Front gripper slipping

Remove and inspect front gripper and gripper guide arm.
Replace if worn.

*

Dirty front and rear gripper
interfaces

Remove and clean surfaces surrounding the grippers.

24

Air leaks when trigger is not
activated

Listen for air leaks. Check red valve , Air lines, and
replace as required. No air leaks allowed. Remove and
replace as required or contact BAND-IT.

28

Worn flip cover and tool
body

Inspect inside of flip cover and bottom of tool body for
excessive wear. Replace flip cover as required. For tool
body wear contact BAND-IT for evaluation.

28

Water or oil in pneumatic
lines.

Purge pneumatic lines and red four way valve assembly.
Install a desiccant air dryer or similar which meets tool set
up requirements).

*

Tool cutting before full
tension applied.

Verify cut-off timing. If required, remove handle cover and
adjust timing valve. Replace if damaged.

28

Premature release of trigger Hold trigger down until tool completes cut off cycle

15

Fluctuating facility air
pressure

Verify if facility air pressure meets tool set up
requirements. Air booster system may be required.

4-8

Worn knife/blade

Remove and replace knife and blade. Refer to
maintenance schedule.

21,22

Timing valve adjustment

Verify timing. If required, remove right side body and
adjust timing valve. Replace if damaged.

28

Rear tension block slipping,
therefore tool does not
reach cut off tension.

Remove and inspect gripper block assembly. Replace as
required.

24

Coiled hose line has air leak Verify no air leaks in coiled hose assembly. Remove and

replace as required.

4-8

Front gripper slipping

Remove and inspect front gripper and gripper guide arm.
Replace if worn.

*

Red four way valve
malfunction

Remove clean and inspect. Replace as required.

*

Worn blade pin or housing

Remove and replace blade pin and/or Maintenance Flip
Cover.

23

Tool will not

tension

properly (i.e.

slipping, slow

etc.)

Tool will not

cut off clamp

tail

Troubleshooting
Matrix