It1000-ab, Troubleshooting matrix, 18 of 38 – BAND-IT IT1000-AB 1/4 Tie-Lok Tool User Manual
Page 18: 1/4” tie-lok, Tool
Document # I17791 Rev H
© Copyright
BAND-IT-IDEX, Inc. 2009
All rights reserved
www.BAND-IT-IDEX.com
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver, CO 80216-0307 USA
P: 1-800-525-0758 F: 1-800-624-3925
18 of 38
IT1000-AB
1/4” Tie-Lok
®
Tool
Symptom
Probable cause
Recommended Fix
Page
Rear tension block slipping,
therefore tool does not
reach cut off tension.
Remove and inspect gripper block assembly. Replace as
required.
24
Front gripper slipping
Remove and inspect front gripper and gripper guide arm.
Replace if worn.
*
Dirty front and rear gripper
interfaces
Remove and clean surfaces surrounding the grippers.
24
Air leaks when trigger is not
activated
Listen for air leaks. Check red valve , Air lines, and
replace as required. No air leaks allowed. Remove and
replace as required or contact BAND-IT.
28
Worn flip cover and tool
body
Inspect inside of flip cover and bottom of tool body for
excessive wear. Replace flip cover as required. For tool
body wear contact BAND-IT for evaluation.
28
Water or oil in pneumatic
lines.
Purge pneumatic lines and red four way valve assembly.
Install a desiccant air dryer or similar which meets tool set
up requirements).
*
Tool cutting before full
tension applied.
Verify cut-off timing. If required, remove handle cover and
adjust timing valve. Replace if damaged.
28
Premature release of trigger Hold trigger down until tool completes cut off cycle
15
Fluctuating facility air
pressure
Verify if facility air pressure meets tool set up
requirements. Air booster system may be required.
4-8
Worn knife/blade
Remove and replace knife and blade. Refer to
maintenance schedule.
21,22
Timing valve adjustment
Verify timing. If required, remove right side body and
adjust timing valve. Replace if damaged.
28
Rear tension block slipping,
therefore tool does not
reach cut off tension.
Remove and inspect gripper block assembly. Replace as
required.
24
Coiled hose line has air leak Verify no air leaks in coiled hose assembly. Remove and
replace as required.
4-8
Front gripper slipping
Remove and inspect front gripper and gripper guide arm.
Replace if worn.
*
Red four way valve
malfunction
Remove clean and inspect. Replace as required.
*
Worn blade pin or housing
Remove and replace blade pin and/or Maintenance Flip
Cover.
23
Tool will not
tension
properly (i.e.
slipping, slow
etc.)
Tool will not
cut off clamp
tail
Troubleshooting
Matrix