It1000-ab, Operating tips, 14 of 38 – BAND-IT IT1000-AB 1/4 Tie-Lok Tool User Manual
Page 14: 1/4” tie-lok, Tool
Document # I17791 Rev H
© Copyright
BAND-IT-IDEX, Inc. 2009
All rights reserved
www.BAND-IT-IDEX.com
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver, CO 80216-0307 USA
P: 1-800-525-0758 F: 1-800-624-3925
14 of 38
IT1000-AB
1/4” Tie-Lok
®
Tool
Tie Installation:
When installing a tie, a random visual check to verify the presence of a dimple after
the tie has been applied is recommended. The dimple is the locking element of an
installed band. The IT1000 forms a dimple into the band with the punch. By
controlling and monitoring the items that are needed to form a good lock, an operator
can help insure that the band will be applied correctly without having to inspect every
assembly.
These items are:
• Adequate air pressure and volume (see page 4,6)
• Setting the tool air pressure (see page 4,6)
• Following recommended PM Schedule (see page 21)
• Fixture mounting the tool properly (see page10-13 )
For Best Performance and to Extend Tool Life:
• Follow preventative maintenance and parts replacement instructions (page 21) at
appropriate service intervals.
• Do not remove factory applied lubrication from inside tool unless performing a
thorough maintenance procedure and then replacing with fresh lubricant
immediately.
• Do not use degreaser in the tool body.
• Do not spray any lubricant or cleaner into the Quick Connect Air Couplings.
• Use nominal recommended tension setting (listed on page 4,6). Higher pressure
may not result in a tighter clamp, but increases the likelihood of clamp tail jamming
and premature worn parts.
• Do not over-tighten Knife Pin access screws. Over torque on these screws may
result in stripping screw threads.
• For maintenance beyond what is described in this manual, consult BAND-IT.