Atop Industrial Wireless Serial Device Server Series
SW550X
User Manual V 1.1

72

4.2.8 UDP Application: Multi-Point Pair Connection

It is also possible to setup pair connection in UDP mode to have more than one Pair

Connection Master or Slave to communicate to each other. For example, it is possible to setup

one Modbus Master and six Modbus Slaves in UDP, Fig. 4. 16. Note again that UDP does not

guarantee data delivery and only data would be transmitted over Ethernet; other serial pings

are not transmited. If RS-232 along with flow control, it is recommended to use Multi-Point Pair

Connection in TCP, see

Sec. 4.2.10

.

Note:

the destination IP and Port of the Slaves need to be equal to the Master’s IP and Port. Local Listening Port of

the

Slaves need to be equal to the Master’s Destination Port, see Table for an example.

Table 4. 1

IP Address

Link Mode

Local Listening Port

Destination IP

Destination Port

SW5501 Master COM1

10.0.50.100

UDP

5000

10.0.50.200~10.0.50.203

5000

SW5501 Master COM1

10.0.50.100

UDP

5001

10.0.50.200~10.0.50.201

5001

SW5502 Slave 1 COM1

10.0.50.200

UDP

5000

10.0.50.100

5000

SW5502 Slave 1 COM2

10.0.50.200

UDP

5001

10.0.50.100

5001

SW5502 Slave 2 COM1

10.0.50.201

UDP

5000

10.0.50.100

5000

SW5502 Slave 2 COM2

10.0.50.201

UDP

5001

10.0.50.100

5001

SW5501 Slave 3 COM1

10.0.50.202

UDP

5000

10.0.50.100

5000

SW5501 Slave 4 COM1

10.0.50.203

UDP

5000

10.0.50.100

5000