Atop Technology SW550X User manual User Manual
Page 46

Atop Industrial Wireless Serial Device Server Series
SW550X
User Manual V 1.1
40
the device’s contact information in case of emergency; “System Name”, usually used to
identify this device; and
“System Location”, usually used to specify the device location.
If you wish to make the device information available for public viewing/editing, Enable the
SNMP function. Fill in the passphrase for the
“Read Community”, the group that is allowed to
read the device information and fill in the passphrase for the
“Write Community”, the group
that is allowed to read/modify the device information. By default SW550X comes in public for
Read Community and private for Write Community. In case the device raises an alert due to
any unexpected incident, a message will be dispatched to a SNMP trap server. Specify the IP
Address of the SNMP Trap Server designed to collect all alert messages; any changes made
will take effect after the device is restarted.
There are five events that will trigger the alarm; these alerts are useful for security control or
security monitoring:
Cold Start, when there is a power interruption.
Warm Start, when the device resets.
Authentication Failure, when an incorrect username or password is entered.
IP Address Changed,
when the device’s IP is changed.
Password Changed, when the administrator password is changed.
Any of the five events would trigger an alert. When enabled, an email alert would be sent to the
designated address in the E-Mail Settings. A Trap alert would be sent to the designated Trap
server in the SNMP Settings.
, to specify the email addresses to which the alert message is sent.