beautypg.com

Atop Technology SW550X User manual User Manual

Page 71

background image

Atop Industrial Wireless Serial Device Server Series
SW550X
User Manual V 1.1

65

 Click on the

COM1 link on the left hand side.

Fig. 4. 10

 Select UDP in the Link Modes.

Destination IP and Port: Specify the Begin and End IP here. Four groups of range

IPs are allowed. This is the IP address of the UDP program and the Port it is listening
to. Note that the maximum number of UDP nodes that SW550X can handle would
highly depend on the traffic load. We have tested that SW550X can handle up to 200
UDP nodes (baud rate 9600 bps, request interval 100ms, and data length 30bytes).

 Enter the Local Listening Port. This is the port that SW550X should listen to. Match

this setting in the UDP program (usually called destination port in the UDP program).

 For serial settings, go to

Sec. 3.8.2

. For Advanced settings, go to

Sec. 3.8.3

.

Scroll to the bottom of the page and click on “Save & Apply” button to save the

changes.