5 serial/ip advanced settings, Serial/ip advanced settings – Atop Technology SW550X User manual User Manual
Page 109

Atop Industrial Wireless Serial Device Server Series
SW550X
User Manual V 1.1
103
5.5 Serial/IP Advanced Settings
In the Serial/IP Control Panel, Click on the Advanced button to open Advanced Settings
window (Fig. 5. 19). Click on Use Default Settings to load the default settings.
Extend Server Connection Maintains the TCP connection for specified amount of time
after COM port is closed
Attempt Server Connection Terminates pending connection attempts if they do not
succeed in the specified time
Synchronize with Server Upon COM Port Open Required by NT Systems (2000, XP,
Vista, 7)
Update Routing Table Upon COM Port Open Maintains IP route to a server in a
different subnet by modifying the IP routing table
Enable Nagle Algorithm Provides better network efficiency by imposing a minor latency
on the data stream while it waits to fill network packets
Always Limit Data Rate to COM Port Baud Rate Limits the data rate to the baud rate
that is in effect for the virtual COM port
Attempt Server Connection If credential is set to Windows Credentials, VCOM
automatically adds the current Windows domain to the username
COM Port Control Keep-Alive Controls the interval at which VCOM will issue the
keep-alive message, if no there is no activity
Maximum Connection Recovery Interval
Controls the maximum time for “Restore
Failed Connection”
Enable SETXON/SETXOFF COM Port Commands This option enables additional
negotiation on SETXON and SETXOFF commands and is only available for the “V”
series serial device servers. If the application requires SETXON/SETXOFF feature,
please contact Atop Tech Support.