3.2 Quick Step-by-Step Manual
The following quick guide is intended for installation of a gateway with basic features
only. For full configuration please read the whole user manual carefully. For a
successful installation of the whole system we recommend you to have a training
certificate from 2N.
Warning
All SIM cards must have the same or disabled PIN code! The
same PIN code must be defined in the gateway configuration.
Basic Configuration – Step by Step
This section will help put your
gateway in operation for
2N StarGate / BlueTower
®
the first time.
Refer to the
subsection for detailed
3.3 Web Configuration Interface
settings.
Install the GSM gateway as instructed in the
Before
subsection.
the first start, remove the SIM cards, or insert the SIM cards with the PIN
request disable.
Connect the GSM gateway to the Ethernet network to enable connection to the
address mentioned in the
subsection from the
3.1 Important Default Settings
configuration terminal. If the gateway default IP address is not suitable for your
Ethernet installation, reset the IP address as follows:
Disconnect the configuration terminal from the Ethernet network.
Disconnect the GSM gateway from the Ethernet network.
Prepare the Ethernet switches, or an Ethernet crossed cable.
With the Ethernet crossed cable, interconnect the configuration terminal
with the GSM gateway directly.
With the Ethernet switch, connect the configuration terminal and GSM
gateway to the pre–prepared Ethernet switch. We do not recommend
connecting any other equipment.
Change the Ethernet IP setting in the configuration terminal, e.g.:
IP=192.168.1.200, Net Mask: 255.255.255.0.
Open your web browser and enter the GSM gateway IP address.
Enter the factory login data.
Change the required settings in the
,
Gateway configuration Ethernet
menu and store the data into the GSM gateway.
configuration
Connect the GSM gateway to a standard Ethernet network.
Restore the configuration terminal IP setting and connect the configuration
terminal to a standard Ethernet network.
Enter the new GSM gateway IP address to get connected to the web
interface.
Enter the current time and date in the
,
menu for
Gateway control Date/Time
the GSM gateway.
Make sure that the
item is
in the
,
Licence status
unlocked
Gateway control
menu. If not, your GSM gateway does not contain the
Firmware/Licence
licence. Contact your dealer for the licence key.
Set the correct PIN value in the
,
Gateway configuration System parameters