beautypg.com

Echo 72854s User Manual

Page 13

background image

9

1. Before starting the hydrostatic pump, make sure

all system components (reservoir, fittings, etc.)
are clean.

2. Fill the reservoir with recommended hydraulic

fluid, which should be filtered before entering
the reservoir.

3. The inlet line leading from the reservoir to the

charge pump must be filled before start-up.
Loosen the fitting at the pump on this inlet line
until oil bleeds out.

Warning! Do not start engine unless pump is
in neutral or detent position on the cable.

4. Start the engine and run at the lowest possible

RPM.

5. Loosen the motor fittings until oil bleeds out to

remove air from the system. Retighten fittings.

6. As air is purged from the unit, the oil level in the

reservoir will drop and bubbles may appear in
the fluid. Refill the reservoir as necessary.

7. Run the feed roller in both directions for several

minutes until any remaining air is purged from
the unit. Refill the reservoir as necessary.

8. Shut down the engine, (or disengage PTO) check

for and correct any fluid leaks, and check the
reservoir level. Add fluid if necessary. The
hydrostatic pump is now ready for operation.

Hydrostatic pressure controlled by the crossover
relief valve is factory set at 1750 PSI. A 2000 PSI
shim kit is available for extreme conditions.