Check to see that the light flashes approximately
once a second when the SRT engine is running.
■
RCD / ELCB (option)
The RCD (Residual Current Device) is located at
the ground and will protect against short circuits to
earth. When there is a short circuit the RCD will
shut down the 230v AC power to the platform outlet.
To reset the outlet disconnect the power tool lead
from the platform box and reset the RCD at the
ground.
If the problem persists call a trained service techni-
cian.
■
Air filter
Visually check the viewing area (1) on the air
cleaner service indicator (2) to see that it is clear. If
it is red, change the air filter and push the reset but-
ton on top of the air cleaner service indicator.
■
Safety prop
Inspect the safety prop(s) to see that it is present
and moves freely.
■
Parking brakes
Visually check to see that the pin (2) is engaging
and that there is enough surface (1) to hold the pin
when it engages. Also check the brake release cam
(3) to see that it moves freely.
SRT2670 – 11360A
page 7 - 9
7. Daily Inspection and Maintenance