Alternator not charging

When the fan belt breaks, or the alternator output
falls below a safe level for other reasons, the engine
automatically shuts off and an alarm sounds. As
long as the SRT battery is charged you can lower
the platform, in the usual way, from the platform
control box or the ground control box without the
engine running.

Outriggers (option)

The SRT cannot be driven unless the outriggers
are completely up. If you have just raised the outrig-
gers but the SRT will not drive, double check to be
sure all four outriggers are completely up.

Circuit Breakers

Main breaker

There is only one circuit breaker, on a standard
SRT, that is accessible to the operator. Its purpose
is to protect the electrical circuits from electrical
overloads. When the circuit breaker trips (pops out)
push it back in then attempt to use the SRT. If the
circuit breaker trips a second time, take the SRT out
of service and refer the problem to a qualified
trained service technician for repair.

RCD / ELCB outlet (option)

The RCD (Residual Current Device) is located at
the ground and will protect against short circuits to
earth. When there is a short circuit the RCD will
shut down the 230v AC power to the platform outlet.

To reset the outlet disconnect the power tool lead
from the platform box and reset the RCD at the
ground.

If the problem persists call a trained service techni-
cian.

page 5 - 2

SRT2670 – 11360A

5. Automatic Shut-offs and Circuit Breakers