4 stabil-trak™ system test, 1 stabil-trak™ system test instructions, 2 stabil-trak™ system test procedures – Lull 944E-42 Service Manual User Manual
Page 222: Stabil-trak™ system test, Stabil-trak, System test -10, Stabil-trak™ system test instructions -10, Stabil-trak™ system test procedures -10

Stabil-TRAK™ System
10-10
944E-42
10.4
STABIL-TRAK™
SYSTEM
TEST
Note: The operator must know that the Stabil-TRAK™
system is active and functioning properly.
To test the function of the Stabil-TRAK™ system, read
the Stabil-TRAK™ System Test instructions and follow
Steps 1 through 9 of Section 10.4.2, “Stabil-TRAK™
10.4.1
Stabil-TRAK™
System
Test
Instructions
• Test the Stabil-TRAK™ system with the machine
on a level surface.
• Remove any attachment from the quick attach
before performing the test.
• DO NOT extend the boom at any time during the
test. Perform the test with the boom fully retracted.
• DO NOT raise the boom above 60° for Steps 3-6.
• DO NOT raise the boom above 45° for Steps 7-9.
• Follow Steps 1 through 9 of the Stabil-TRAK™
system test procedure exactly as written.
Note: If the Stabil-TRAK™
light goes OFF and the front
left tire lowers to the ground at any time during Steps 4
through 7, the test was not performed properly or the
Stabil-TRAK™
system is not functioning properly.
Carefully repeat the steps starting with Step 1.
If the Stabil-TRAK™ light goes OFF and the front left tire
lowers to the ground consistently during Steps 4 through 7,
the Stabil-TRAK™ system is not functioning properly and
the test should be stopped immediately. If the Stabil-
TRAK™ system is not functioning properly, follow the
procedures in Section 10.5.2, “Stabil-TRAK™ Hydraulic
Circuit,” to repair the system.
Note: The front left tire off the ground during the test is a
visible indication that the stability system is in the locked
mode.
10.4.2
Stabil-TRAK™
System
Test
Procedures
If Steps 1 through 9 prove positive, the Stabil-TRAK™
system is functioning properly, and the machine can be
returned to service. If any of these steps indicate that the
Stabil-TRAK™ system is not functioning properly, follow
the procedures in Section 10.5.2, “Stabil-TRAK™ Hydraulic
Circuit,” to repair the system.