Lull 944E-42 Service Manual User Manual
Page 202

Electrical System
9-44
944E-42
527
702
3
Amber
Circuit - Voltage
Auxiliary Input/Output 2 Circuit - Voltage Above
Normal, or Shorted to High Source
528
93
2
Amber
Switch - Data
Auxiliary Alternate Torque Validation Switch -
Data Erratic, Intermittent, or Incorrect
529
703
3
Amber
Circuit - Voltage
Auxiliary Input/Output 3 Circuit - Voltage Above
Normal, or Shorted to High Source
546
94
3
Amber
Fuel Delivery
Pressure
Fuel Delivery Pressure Sensor Circuit - Voltage
Above Normal, or Shorted to High Source
547
94
4
Amber
Fuel Delivery
Pressure
Fuel Delivery Pressure Sensor Circuit - Voltage
Below Normal, or Shorted to Low Source
551
558
4
Amber
Accelerator Pedal
Low Idle Switch
Accelerator Pedal or Lever Idle Validation
Circuit - Voltage Below Normal, or Shorted to
Low Source
553
157
16
Amber
Injector Metering
Rail 1 Pressure
Injector Metering Rail #1 Pressure High - Data
Valid but Above Normal Operational Range -
Moderately Severe Level
554
157
2
Amber
Injector Metering
Rail 1 Pressure
Fuel Pressure Sensor Error - Data Erratic,
Intermittent, or Incorrect
559
157
18
Amber
Injector Metering
Rail 1 Pressure
Injector Metering Rail #1 Pressure Low - Data
Valid but Below Normal Operational Range -
Moderately Severe Level
584
677
3
Amber
Starter Solenoid
Lockout Relay Driver
Circuit
Starter Relay Circuit - Voltage Above Normal, or
Shorted to High Source
585
677
4
Amber
Starter Solenoid
Lockout Relay Driver
Circuit
Starter Relay Circuit - Voltage Below Normal, or
Shorted to Low Source
595
103
16
Amber
Turbocharger 1
Speed
Turbocharger #1 Speed High - Data Valid but
Above Normal Operational Range - Moderately
Severe Level
596
167
16
Amber
Alternate Potential
(voltage)
Electrical Charging System Voltage High - Data
Valid but Above Normal Operational Range -
Moderately Severe Level
597
167
18
Amber
Alternate Potential
(voltage)
Electrical Charging System Voltage Low - Data
Valid but Below Normal Operational Range -
Moderately Severe Level
598
167
1
Red
Alternate Potential
(voltage)
Electrical Charging System Voltage Low - Data
Valid but Below Normal Operational Range -
Most Severe Level
Fault
Codes
SPN
Codes
FMI
Codes
Lamp
Color
SPN Description
Cummins Description