Lull 1044C-54 Series II Service Manual User Manual
Page 358

Axles and Brakes
9-14
31200079
Precautions
WARNING: Never fill an accumulator with oxygen! An explosion could
result if oil and oxygen mix under pressure. Always fill an 
accumulator with dry nitrogen. Nitrogen gas is free of water 
vapor and oxygen which makes it harmless to parts and is 
safe to use.
CAUTION: Never fill an accumulator with air. When air is compressed,
water vapor condenses and can cause corrosion. This may 
damage seals and ruin the accumulator.
CAUTION: Never charge an accumulator to a pressure more than that
specified. Pressure should be 375–425 psi.
WARNING: Always release all hydraulic pressure before removing an
accumulator from the system.
CAUTION: Before disassembling an accumulator, release both gas and
hydraulic pressure. When disassembling an accumulator, 
make sure that dirt and abrasive materials do not enter any 
openings.
Pre-Charging Accumulator
Note: Replacement accumulators shipped from the factory are not pre-charged.
Make sure the nitrogen bottle, as well as the charging and gauging 
assembly used, is compatible with the gas valve assembly. The nitrogen 
source and all components must be rated for a pressure at least as high as 
the nitrogen source. It is strongly recommended that the nitrogen bottle 
has a high pressure regulator. Nitrogen gas bottles for water-pumped 
nitrogen have right-hand valve threads and are used with accumulators up 
to 3000 psi. 