Engine Data Management

Fuel Flow Option Programming Procedure

Setting the K factor

This procedure is different than for setting other parameters. Place the
select switch in the FF position. If you haven’t already done so, start the
pilot programming procedure, simultaneously hold the STEP and LF
buttons for five seconds. You will see the word

PROGRAM

for two seconds.

1. Tap STEP button to advance to the KF-SET screen

29.00=KF

2. Hold both the STEP and LF buttons simultaneously for five seconds.

First digit flashes (shown here as a larger digit only for illustration

purposes):

2

9.00

3. Tap or hold the LF button to change flashing digit:

I

9.00

4. Tap STEP button for next digit:

I

9

.00

5. Tap or hold the LF button to change flashing digit:

I

8

.00

6. Tap STEP button for next digit:

I8.

0

0

7. Repeat items 5 and 6 for the remaining two digits.
8. Hold STEP and LF buttons simultaneously for five seconds to exit.

Accumulate Total—Trip Total

Select “No” if you wish to display total fuel used since the last time you
informed the EDM that the aircraft was refueled. Select “Yes” to display
total fuel used for an extended trip with multiple fuel stops. This
selection affects only the

USD

parameter.

GPS-C Comm settings

The GPS-C setting selects the format of the fuel data output of the EDM.
See “

GPS-C Fuel Flow Format” on page 46.

Section 12 - Programming Long Term Data Memory

If you haven’t already done so, start the pilot programming procedure,
simultaneously hold the STEP and LF buttons for five seconds. You
will see the word

PROGRAM

for two seconds. To change the date, time and

user id for the Long Term Data Memory, tap the STEP button until the
display shows

DUMP? N

. Next, simultaneously hold the STEP and LF

buttons for five seconds. Then set the date and time as show below: