J.P. Instruments EDM 700/800/711 Pilots Guide User Manual
Page 44

Page 40
Engine Data Management
Fuel Flow Option Programming Procedure
Setting the K factor
This procedure is different than for setting other parameters. Place the
select switch in the FF position. If you haven’t already done so, start the
pilot programming procedure, simultaneously hold the STEP and LF
buttons for five seconds. You will see the word
PROGRAM
for two seconds.
1. Tap STEP button to advance to the KF-SET screen
29.00=KF
2. Hold both the STEP and LF buttons simultaneously for five seconds.
First digit flashes (shown here as a larger digit only for illustration
purposes):
2
9.00
3. Tap or hold the LF button to change flashing digit:
I
9.00
4. Tap STEP button for next digit:
I
9
.00
5. Tap or hold the LF button to change flashing digit:
I
8
.00
6. Tap STEP button for next digit:
I8.
0
0
7. Repeat items 5 and 6 for the remaining two digits.
8. Hold STEP and LF buttons simultaneously for five seconds to exit.
Accumulate Total—Trip Total
Select “No” if you wish to display total fuel used since the last time you
informed the EDM that the aircraft was refueled. Select “Yes” to display
total fuel used for an extended trip with multiple fuel stops. This
selection affects only the
USD
parameter.
GPS-C Comm settings
The GPS-C setting selects the format of the fuel data output of the EDM.
See “
GPS-C Fuel Flow Format” on page 46.
Section 12 - Programming Long Term Data Memory
If you haven’t already done so, start the pilot programming procedure,
simultaneously hold the STEP and LF buttons for five seconds. You
will see the word
PROGRAM
for two seconds. To change the date, time and
user id for the Long Term Data Memory, tap the STEP button until the
display shows
DUMP? N
. Next, simultaneously hold the STEP and LF
buttons for five seconds. Then set the date and time as show below: