J.P. Instruments EDM 700/800/711 Pilots Guide User Manual
Page 37
For Your Safe Flight
Page 33
4. Remove the USB flash drive from the USB connector.
This completes the download. Continue to the next step.
Downloading from USB Flash Drive to a PC
To download your data from the USB flash drive to your PC,
follow these easy steps.
1. On your PC, start the EzTrends program.
2. Plug in the USB flash drive into an available USB port.
3. In EzTrends, select the Move and Plot Data from Memory Stick
option.
4. In the displayed list, find the USB flash drive and double click it.
5. Select the file you wish to plot and then select the flight in that file.
Refer to the EzTrends manual for details on how to use EzTrends.
Section 7 - Personalizing
Pilot Programming
To start the Pilot Programming Procedure, simultaneously hold the
STEP and LF buttons for five seconds. You will see the word
PROGRAM
for two seconds and then the sequence shown in the chart below. Tap the
STEP button to advance to the next item in the list. Tap the LF button to
select alternate values of that item. The shaded areas in the chart below
pertain only to the Fuel Flow Option.
S
e
le
c
t
s
w
it
c
h
Tap STEP
to advance
to the next
item
Tap LF to
sequence
through
these
values
Comments
T, F,
A
PROGRAM
Stays on for two seconds. Hold both buttons
for 5 seconds set up the factory original TIT
(see page 36).
T, F,
A
FUEL? N
N Y
Y—Yes—to change fuel status (see page
26).
T, A
RATE 4
0 …9
Index rate (pause time) in the Automatic
Mode. 0 disables the Automatic Mode
(except EDM-711).
T, A
OATF
OAT F
OAT C
To calibrate the OAT
10°, hold both the
STEP and LF buttons simultaneously for
five seconds, which will proceed to the next
step. Otherwise the next step will be
skipped.