J.P. Instruments EDM 700/800/711 Pilots Guide User Manual
Page 38

Page 34
Engine Data Management
T, A
OAT0
OAT-I0 …
OATI0
This step will be normally be skipped.
Adjust the indicated temperature up or down
by up to 10°. For example,
OAT3 adjust the
OAT 3° higher.
T, A
EGT I?N
EGT I?N
EGT
I?Y
Y—Yes—sets the digital display to one-
degree resolution; N—No—sets 10°. (10°
resolution is easier to interpret the EGTs.)
HP- ? Y
N Y
Y—Yes—displays %HP in the upper digital
window. N—No—displays RPM in the upper
digital window. Hold STEP and LF for 5
seconds to adjust the horsepower constant.
T, A
70
HP
HPC= I25
%HP display will change when HP constant
is adjusted. See Programming the EDM-800
Horsepower Constant beginning page 35.
Hold STEP and LF for 5 seconds to set the
MAP calibration. Tap STEP to exit.
T, A
MAP+0
Correct the MAP to the altimeter setting at a sea
level airport ±3.0 in Hg. Hold Step/OK and
Change for 5 seconds until you see ADJUST to
set the MAP calibration. Tap Step/OK to
continue to the next step.
F, A
KF-SET
29.00=KF
KF-set, hold both STEP and LF buttons
simultaneously for five seconds to begin the
next sequence.
29.00=KF
2
9.00 One digit will be flash and the LF
button will adjust up or down. STEP to next
digit.
Hold both buttons to exit set mode.
F, A
ACCUM?N
ACCUM?N
ACCUM?Y
N—No—Upon informing the EDM that you
refueled the aircraft, reset total fuel used to
0.
Y—Yes—accumulate total fuel used rather
than reset to 0 at each refueling.
F, A
GPS - C = 2 0 … 6
GPS Com Format.
T, F,
A
DUMP? N
N NEW
ALL
Memory dump. Select to transfer ALL or
only NEW data. The
END Y
step is skipped
after a successful a Long Term Memory
DUMP.
T, F,
A
END Y
END Y
END N