beautypg.com

J.P. Instruments EDM 700/800/711 Pilots Guide User Manual

Page 38

background image

Page 34

Engine Data Management

T, A

OAT0

OAT-I0 …
OATI0

This step will be normally be skipped.

Adjust the indicated temperature up or down
by up to 10°. For example,

OAT3 adjust the

OAT 3° higher.

T, A

EGT I?N

EGT I?N
EGT
I?Y

Y—Yes—sets the digital display to one-
degree resolution; N—No—sets 10°. (10°
resolution is easier to interpret the EGTs.)

HP- ? Y

N  Y

Y—Yes—displays %HP in the upper digital
window. N—No—displays RPM in the upper
digital window. Hold STEP and LF for 5
seconds to adjust the horsepower constant.

T, A

70

HP

HPC= I25

%HP display will change when HP constant
is adjusted. See Programming the EDM-800
Horsepower Constant beginning page 35.
Hold STEP and LF for 5 seconds to set the
MAP calibration. Tap STEP to exit.

T, A

MAP+0

Correct the MAP to the altimeter setting at a sea
level airport ±3.0 in Hg. Hold Step/OK and
Change for 5 seconds until you see ADJUST to
set the MAP calibration. Tap Step/OK to
continue to the next step.

F, A

KF-SET

29.00=KF

KF-set, hold both STEP and LF buttons
simultaneously for five seconds to begin the
next sequence.

29.00=KF

2

9.00 One digit will be flash and the LF

button will adjust up or down. STEP to next
digit.

Hold both buttons to exit set mode.

F, A

ACCUM?N

ACCUM?N


ACCUM?Y

N—No—Upon informing the EDM that you
refueled the aircraft, reset total fuel used to
0.
Y—Yes—accumulate total fuel used rather
than reset to 0 at each refueling.

F, A

GPS - C = 2 0 … 6

GPS Com Format.

T, F,

A

DUMP? N

N  NEW 
ALL

Memory dump. Select to transfer ALL or

only NEW data. The

END Y

step is skipped

after a successful a Long Term Memory
DUMP.

T, F,

A

END Y

END Y 
END N

Y—Yes to exit; N—No to review list again.